burnham

V9 Series

The sectional design of Burnham's V9 boiler makes it ideal for use in light commercial installations where the boiler room is not easily accessible. The V9 features a wet-base, forced draft design that eliminates the need for a special base, combustion chamber, or mechanical equipment to artificially induce proper draft. It is versatile enough to meet most plan and spec job requirements, v9 seriesand the V9 can be installed in a confined area requiring only 9 inches from a right side wall and 6½ feet of vertical clearance. Not to mention the fact that assembly of the cast iron sections and nipples is easily accomplished by using short draw rods, a ratchet, and a wrench.

Key Features:

  • Simple assembly with draw rods, ratchet and wrench
  • Oil, gas or combination gas/oil
  • Water or steam
  • Cast-iron sectional design
  • Top or rear flue outlet
  • 346 to 1,900 MBH capacity


V11 Series

Burnham's V11 series boiler is built to last using durable cast-iron and an assembly method preferred by mechanical contractors and building owners. The V11 series is adaptable and easily installed into commercial boiler rooms by simply joining the cast-iron sections with cast-iron nipples using short draw rods, a ratchet, and wrench. Additionally, top or rear venting allows for easy chimney or outside wall venting. The V11 series boiler is available in 20 sizes with gross output ratings from 667 to 4,551 MBH, and has the power to handle virtually all commercial heating loads.v11 series

Key Features

  • Simple assembly with draw rods, ratchet, and wrench
  • Oil, gas or combination gas/oil
  • Water or steam
  • Cast-iron sectional design
  • Top or rear flue outlet
  • 667 to 4,551 MBH capacity

Boiler Number Boiler H.P. Gross Output I=B=R Net Rating Burner Input Firebox Vol. Firebox Pres. I=B=R Vent Dia. Approx. Weight
MBH Steam MBH Steam Sq Ft Water MBH Oil GPH Gas MBH Cubic Feet (water) Inches Pounds
V1104 19.9 667 500 2083 580 5.8 837 7.9 0.35 8 2105
V1105 25.6 857 643 2679 745 7.4 1068 10.6 0.36 8 2510
V1106 31.9 1069 802 3342 930 9.2 1328 13.2 0.37 8 2920
V1107 38.3 1281 963 4013 1114 11.0 1588 15.9 0.42 10 3325
V1108 45.3 1517 1159 4829 1319 13.0 1876 18.5 0.42 10 3733
V1109 51.7 1729 1335 5563 1503 14.8 2136 21.1 0.39 10 4147
V1110 58.0 1941 1507 6279 1688 16.6 2396 23.8 0.42 12 4557
V1111 64.3 2154 1672 6967 1873 18.4 2656 26.5 0.40 12 4964
V1112 69.7 2354 1812 7550 2030 20.0 2887 29.1 0.42 12 5374
V1113 74.8 2503 1943 8096 2177 21.5 3103 31.8 0.40 12 5771
V1114 81.6 2730 2120 8833 2374 23.5 3392 34.4 0.38 14 6184
V1115 88.3 2957 2296 9567 2571 25.5 3680 37.1 0.36 14 6601
V1116 93.4 3126 2427 10113 2718 27.0 3897 39.7 0.38 14 7008
V1117 100.2 3353 2603 10846 2916 29.0 4186 42.4 0.41 14 7417
V1118 106.9 3580 2780 11583 3113 31.0 4474 45.0 0.39 16 7823
V1119 111.7 3739 2903 12096 3251 32.5 4691 47.7 0.38 16 8231
V1120 118.2 3957 3072 12800 3441 34.5 4979 50.3 0.38 16 8683
V1121 124.7 4174 3241 13504 3630 36.5 5268 53.0 0.40 16 9053
V1122 129.5 4334 3365 14021 3769 38.0 5485 55.6 0.41 18 9456
V1123 136.0 4551 3533 14721 3957 40.0 5773 58.3 0.43 18 9865